#Hunter air conditioning control panel manual manuals#
Note: None of the reset functions will erase the Easy Retrieve "backup", if one has been made. Browse through our list of operation manuals or enter your search below to find the right manual for you. If + is pressed again, the selection will be reset. Press the + button to select it.Ī confirmation message will appear. Use the up and down arrows to highlight the desired type of Reset. Names: Clears all user-programmed names, including Programs, Stations, and SSG's.Īll Data: Clears all of the above items, and the controller returns to the original out-of-the-box programming state. Logs: Clears all Station alarm logs and Controller alarm logs. Programs: Erases Day schedules, start times and run times.įlow Totals: Clears the running flow total histories (they will restart with 0.0 for all entries), only. The display will show the following Reset options:

12:00 will flash on the display, now the controller can be reprogrammed.After two seconds the screen will go blank and 4 segments will appear.From the Time and Day display, press and hold the, and keys.Remove the 9V battery from the controller and wait 1 minute.While holding down the three buttons, press and release the Reset button on the back of the front panel.Hold down the, and program buttons simultaneously.Pro-C (older models)(with Manual All Station dial position) Press and release the RESET button on the back of the front panel.Pro-C (newer models)(with Seasonal Adjust Dial Position) All the memory has been cleared and the controller may now be reprogrammed. When 'DONE' appears on the LCD, release the, and buttons.Press and release the RESET button on the right side of the controller.Press and release the RESET button in the lower wiring compartment.Plug the controller's transformer back in.Greenhouse, Nursery, and Open-Field Irrigation.NOTE: Controllers hardwired to the power source will need to be tested by a qualified electrician. The normal voltage on these two terminals would be between 24-28 VAC. If you have a multimeter, you could also try testing for POWER on the two AC terminals inside the controller's wiring compartment. If the display goes blank after removing the battery, the transformer could be damaged and may need to be replaced. To verify that you have power to the outlet, disconnect the backup battery from the controller.Have an electrician check your GFI, circuit breaker, and electrical outlet if you do not have power to the outlet. If you do not have power to the outlet, check all wall switches, timers, or power strips that may be connected to the outlet.If your controller is not plugged into a wall outlet, the power source is hardwired. Check the power source by plugging a lamp or radio into the wall outlet to verify there is power at the outlet.The controller is running on the power supplied by the backup battery. The NO AC display is a diagnostic message telling you that the controller has stopped receiving AC power. Note: Controllers that are hardwired to the power source will need to be tested by a qualified electrician.

If you a have a mutli meter you could also try testing for 24VAC on the two AC terminals inside the controllers wiring compartment. To verify that you have power to the outlet, disconnect the backup battery from the controller. If you do not have power to the outlet, check all wall switches, timers, or power strips that may be connected to the outlet. Overflowing Condensation Pan Causes and Solution 7.

No Heat in HEAT Mode Causes and Solution 6. Activation of High-Pressure Switch in HEAT Mode Causes and Solution 5. If your controller is not plugged into a wall outlet, the power source is hardwired. The AC Does Not Power On Causes and Solution 3. Check the power source by plugging a lamp or radio into the wall outlet to verify there is power at the outlet. Pro-C - "NO AC" on Display The "NO AC" display is a diagnostic message telling you that the controller has stopped receiving AC power.